9-4
PRESSURE SYSTEM TIPS
DO NOT attempt to tighten, repair or replace any fitting, line or component
when there is pressure in the cooking well. Hot oil could spray out under
pressure causing serious burns.
COMPLAINT CAUSE REMEDY
No pressure
1. Pressure regulating valve
OPEN
2. Pressure regulating valve
dirty or blocked open
3. Leaks around cover O-ring
4. Cover cold
5. Low cooking oil
temperature
6. Faulty safety relief valve
7. Pressure valve out of
adjustment
8. Faulty pressure gauge
1. CLOSE
2. Use repair kit
3. Replace O-ring and center
cover
4. Pre-heat cover
5. Check programmed
temperature
6. Replace
7. Adjust
8. Replace
Excess pressure
1. Restriction in exhaust
system
2. Overloaded with fresh
product
3. Faulty pressure gauge
1. Locate, remove then clean
2. Decrease load
3. Replace