A-5
GF Series
Installation and Operation Manual
X-TMF-GF Series-MFC-eng
Part Number: 541B137AAG
March, 2010
Appendix A: Product Description Code
GF1XX Ordering Instructions
Refer to the Product Description Codes on the previous pages. Starting from the left, choose the product code
options as follows:
1. Required performance model.
a.Standard Performance, non-PTI: GF100
b.High Performance, non-PTI: GF120
c.High Performance, w/ PTI: GF125
2. Configurability
a.Disabled: X, Default on GF100 (optional price adder for Configurability)
b.Enabled: C, Standard on GF120 & GF125
3. Specialty Application
a.High Accuracy, for GF125 only: HA
b.Safe Delivery, for GF120 only: SD
c.No Specialty App: XX
4. Valve Configuration
a.Normally Closed: C
b.Normally Open: O
5. Gas or SH MultiFlo Bin
a.If Gas Specific, enter SEMI gas code: ex. 0013, for N2
b.If SH MuliFlow Bin: SHnn, nn being the required SHBin, 40 - 50
6. Maximum Flow
a.If Gas Specific, enter maximum range in sccm, "C" or slm "L": ex. 500C
b.If SH Bin, enter defined maximum flow: ex. 860, choosing SH44, 281 - 860 sccm
7. Fitting
a.Enter 2-character option code as defined: ex. CX, 1 1/8" C Seal 92mm
8. Downstream Condition
a.Outlet to Vacuum: V
b.Outlet to Atmosphere: A
9. Sensor
a.Orthogonal: O, this is default, non-selectable
10.Connector
a.Enter 2-character option code as defined: ex. DX, DeviceNet
11.CSR
a.Customer Special Requirement, contact Brooks Apps Engineering for review of requirement and
creation of CSR: nnnn
b.If DNET connector, CSR required to define DNET attributes: 0924, generic, ODVA Std. configuration
c.None Required: XXXX
12.Auto Shut-Off.
a.Enabled: A
b.Disabled: X
13.Auto Zero
a.Enabled: A
b.Disabled: X
14.Reference Temperature, Operating Temperature in Degrees C
a.0
o
C Reference Calibration (Standard): 000, default
b.21
o
C Reference Calibration (Normal): 021
c.Customer to specify, range between 10
o
C and 50
o
C: nnn
Here is an example of a configured Product Description Code (PDC) for a GF125, Configurable, no Specialty
Application, Valve Normally Closed, MultiFlo for 281-860 sccm, 1 1/8" C Seal 92mm, outlet to Vacuum, default
sensor, DNET, no CSR, Auto Shut Off enabled, Auto Zero disabled and Default Reference Temperature:
GF125CXXC-SH44860C-CXVODX-0924AX-000