5-17
Confidential
For details about the worker switches, refer to the document separately issued.
< Operating Procedure >
(1) Press the 1 and 0 keys in this order in the initial stage of the maintenance mode.
The machine displays the "WSW00" on the LCD.
(2) Enter a worker switch number to be modified.
The following appears on the LCD:
Selector 1 Selector 8

WSWXX = 0
0 0 0 0 0 0 0
(3) Press the or key to move the cursor to the selector position to be modified. Press the 0
or 1 key to change the setting.
(4) Press the SET key. This operation saves the newly entered selector values onto the
EEPROM and readies the machine for accepting a worker switch number ("WSW00").
(5) Press the Stop key to return the machine to the initial stage of the maintenance mode.
Notes • To cancel the setting and return to the initial stage of the maintenance mode, press the
Stop key.
• If there is a pause of more than one minute after a single-digit number is entered for
double-digit firmware switch numbers, the machine automatically returns to the initial
stage of the maintenance mode.
WSW No. Function
WSW40 V.34 modem settings
WSW41 ON-duration of the scanning light source
WSW42 Internet mail settings
WSW43 Function setting 16
WSW44 Speeding up scanning-1
WSW45 Speeding up scanning-2
WSW46 Monitor of power ON/OFF state and parallel port kept at high
WSW47 Switching between high- and full-speed USB
WSW48 USB setup latency
WSW49 End-of-copying beep
WSW50 SDAA settings
WSW51 Function setting 17
WSW52 Function setting 18
WSW53 Function setting 19
WSW54 Function setting 20
WSW55 Execution interval switching of developing bias voltage correction
WSW56 Function setting 21
WSW57 Function setting 22
WSW58 Function setting 23
WSW59 Function setting 24
WSW60 Function setting 25
WSW61 Scanning light intensity stability judgement 1
WSW62 Scanning light intensity stability judgement 2
WSW63 Function setting 26