S-7300A
6. USING THE OPERATION PANEL (ADVANCED OPERATIONS)
52
Panel operation settings (300 to 399)
No. Setting range
Initial
value
Setting
units
Setting details
300
1 - 2
1
1
Movement when bobbin counter warning.
1: Sewing can continue by pressing the return key
2: Sewing is only possible when lower thread counter is reset after replacing
the bobbin.
301
0, 1
0
1
Program common function / program individual function settings
Needle up/ down
0: Program common function
1: Program individual function
302
0, 1
0
1 Program common function / program individual function settings
Thread trimming lock
0: Program common function
1: Program individual function
303
0, 1
0
1 Program common function / program individual function settings
Thread wiper
0: Program common function
1: Program individual function
304
0, 1
0
1 Program common function / program individual function settings
Correction sewing
0: Program common function
1: Program individual function
305
0, 1
1
1 Program common function / program individual function settings
AUTO/ auto thread trimming
0: Program common function
1: Program individual function
306
0, 1
0
1
Program common function / program individual function settings
Slow start
0: Program common function
1: Program individual function
307
0, 1
1
1
Program common function / program individual function settings
Special locus
0: Program common function
1: Program individual function
308
0, 1
1
1
Program common function / program individual function settings
Best PFM mode
0: Program common function
1: Program individual function
309
0, 1
1
1
Program common function / program individual function settings
X-over seam assist mode
0: Program common function
1: Program individual function
310
OFF,
30 - 300
(sec)
60
30
Automatic panel lock ON standby time
OFF: Automatic panel lock is disabled
30 - 300: Panel open time before panel lock turns on (sec)
* The standby time is only counted at the home screen.
If any other screen is displayed, the panel lock does not operate.
311
OFF, ON
ON
Panel auto lock when turn on power
OFF: Disabled
ON : Enabled

Table of Contents