Operating Instructions
Control panel
Logamatic 4321/4322
6 720 617 492 - 11/2008 US/CA
For the user
Please read carefully
before use

Table of Contents

Question and Answer IconNeed help?

Do you have a question about the Buderus Logamatic 4321 and is the answer not in the manual?

Buderus Logamatic 4321 Specifications

General IconGeneral
BrandBuderus
ModelLogamatic 4321
CategoryControl Panel
LanguageEnglish

Summary

Control Panel Overview

Introduction to the Logamatic Control Panel

Understanding Your Heating System

Heating System Operation Explained

Heating Control Panel Calculations

Heating Control Modes Explained

Heating System Timers and Zones

Energy-Efficient Heating Tips

Safety Information

Manual Overview and Designation

Information about the manual and the intended use of the control panels.

Standards and Symbols

Guidelines on regulations, standards, and understanding safety symbols.

Crucial Safety Instructions

Essential notes and warnings for safe operation and to prevent hazards.

Safety Information

Cleaning and Disposal

Procedures for cleaning the control panel and proper disposal of materials.

Controls and MEC2 Remote Control

Controls on the Basic Unit

Identifies and explains the physical controls on the main unit.

Controls and MEC2 Remote Control

MEC2 Remote Control Operation

Details the functionality of the MEC2 remote control's display, dial, and buttons.

Controls and MEC2 Remote Control

MEC2 Remote Control Interface

Explains the layout and function of the MEC2 remote control buttons and display elements.

Controls and MEC2 Remote Control

Switching the Control Panel On/Off

Step-by-step guide for powering the control panel on and off.

Basic Functions

Simple Operation

Outlines the basic operations controlled via keypad or dial.

Basic Functions

Permanent Display Options

Describes the different types of factory-set permanent displays available.

Basic Functions

Selecting Operating Modes

Explains how to choose between automatic and manual operating modes.

Basic Functions

Automatic Mode Operation

Details how automatic mode uses timer programs for heating.

Basic Functions

Manual Mode Operation

Explains how to select constant day or night mode manually.

Basic Functions

Setting Room Temperature (Current Mode)

Guides on adjusting room temperature for the active heating mode.

Basic Functions

Setting Room Temperature (Inactive Mode)

How to adjust temperature for modes not currently active.

Basic Functions

Heating Domestic Hot Water (DHW)

Information on operating DHW heating and its energy-conscious use.

Basic Functions

Setting DHW Temperature and Single Charge

How to set DHW temperature and initiate a single DHW charge.

Extended Functions

Buttons for Extended Functions

Identifies buttons located behind the MEC2 flap for advanced settings.

Extended Functions

Controlling Extended Functions

Explains the "Push and turn" principle for accessing extended functions.

Displaying Operating Values

How to view various operating values of the heating system.

Extended Functions

Changing Permanent Display Settings

Customizing what information is shown on the permanent display.

Extended Functions

Setting Date and Time

Instructions for setting the system's date and time accurately.

Extended Functions

Selecting a Heating Zone

How to choose a specific heating zone for adjustments.

Extended Functions

Adjusting Room Temperature for Other Zones

Modifying room temperature for different heating zones.

Extended Functions

Adjusting Room Temperature for Other Zones (Details)

Further details on adjusting room temperature for specific zones or modes.

Extended Functions

Heating Zones with MEC2 Control

Explains differences between MEC heating zones and individual zones for adjustments.

Extended Functions

Understanding Heating Programs

Explains what heating programs are and how they work.

Extended Functions

DHW Timer Program

Setting custom timer programs for DHW heating.

Extended Functions

Selecting a Standard Heating Program

How to choose and activate one of the eight preset heating programs.

Extended Functions

Summary of Standard Heating Programs

Table summarizing the settings for various standard heating programs.

Extended Functions

Modifying Programs by Moving Set Points

How to adjust program times and set points.

Extended Functions

Modifying Programs by Moving Set Points (Details)

Further steps for modifying program set points and weekdays.

Extended Functions

Setting Warm Weather Shut Down (WWSD)

Configuring the automatic shut down based on outdoor temperature.

Extended Functions

Setting WWSD Temperature Modes

How to set changeover, continuous summer, and continuous winter modes.

Extended Functions

Setting DHW Operating Mode

Options for operating DHW heating (constant, automatic, off).

Extended Functions

Setting DHW Recirculation Pump Mode

Configuring operating modes for the DHW recirculation pump.

Extended Functions

Setting the Vacation Function

How to activate and configure the vacation mode for reduced heating.

Extended Functions

Vacation Function Details and Cancellation

Further details on vacation function settings and how to cancel it.

Extended Functions

Interrupting and Continuing Vacation Function

Procedures for temporarily pausing and resuming the vacation mode.

Extended Functions

Party and Pause Function

Setting temporary modes for parties or short absences.

Extended Functions

Room Temperature Matching (Calibration)

How to calibrate the room temperature display for accuracy.

Extended Functions

Automatic Maintenance Message

Information on automatic service notifications for maintenance.

Additional Programming Options

Inserting Set Points into Programs

How to add new time/temperature set points to existing programs.

Additional Programming Options

Inserting Set Points Details

Step-by-step guide for inserting set points into a heating program.

Additional Programming Options

Inserting Set Points Workflow

Completing the set point entry and saving the modified program.

Additional Programming Options

Deleting Set Points from Programs

How to remove specific time/temperature set points from programs.

Additional Programming Options

Deleting Set Points Workflow

Completing the set point deletion and saving the modified program.

Additional Programming Options

Deleting Heating Phases

How to remove entire heating phases (start and stop points) from programs.

Additional Programming Options

Deleting Heating Phases Workflow

Completing the heating phase deletion and saving the modified program.

Additional Programming Options

Linking Consecutive Heating Phases

How to join two heating phases to create continuous heating.

Additional Programming Options

Linking Heating Phases Workflow

Completing the heating phase linking and saving the modified program.

Additional Programming Options

Creating a New Heating Program

Step-by-step guide to creating entirely new custom heating programs.

Additional Programming Options

Creating New Program Set Points (Part 1)

Entering the first set of day, time, and temperature for a new program.

Additional Programming Options

Creating New Program Set Points (Part 2)

Entering subsequent set points and finalizing the new program.

Additional Programming Options

Creating a New DHW Program

How to create custom programs for DHW heating independently.

Additional Programming Options

Creating New DHW Recirculation Pump Program

Setting up custom programs for the DHW recirculation pump.

Modules and Their Functions

Module Overview and Compatibility

Lists installed and optional modules for Logamatic 4321/4322.

Modules and Their Functions

ZM434 Burner and Boiler Circuit Module

Details the functions and indicators of the standard ZM434 module.

Modules and Their Functions

ZM434 Module Burner/Boiler Circuit Functions

Explains burner and boiler circuit operations via manual switches and LEDs.

Modules and Their Functions

FM441 Function Module (Heating Zone/DHW)

Describes the FM441 module's control of one heating zone and one DHW consumer.

Modules and Their Functions

FM441 Module Heating Zone/DHW Consumer Controls

Explains manual switches and LED indicators for FM441 module functions.

Modules and Their Functions

FM442 Function Module (Heating Zones)

Details the FM442 module's control of two heating zones with mixing valves.

Boiler Flue Gas Test

Performing the Flue Gas Test

Instructions on how to initiate and conduct the boiler flue gas test.

Correcting Faults and Troubleshooting

Overview of Potential Faults

Lists various faults that may be reported by the control panel.

Correcting Faults and Troubleshooting

Simple Troubleshooting Guide

A table of common observations, causes, and actions for basic issues.

Correcting Faults and Troubleshooting

Detailed Troubleshooting Table

Lists specific faults, their effects, and recommended remedies.

Operation in the Event of a Fault

Emergency Operation Procedures

Instructions for operating the system during electronic failures or emergencies.

Operation in the Event of a Fault

Heating Mode with Manual Switch

How to operate the heating system manually using module switches.

Operation in the Event of a Fault

Emergency Operation Settings Summary

Table summarizing settings for various fault scenarios and emergency operation.

Setup Log

Operating Values and Heating Zone Assignment

Records factory settings and allows for heating zone configuration.