Operation with the user menu
Logamatic EMS – 6 720 801 386 2011/05
42
5
Domestic hot water (DHW) DHW circulation pump (CP)
1)
1) This function depends on the boiler used.
Holiday
set as
DHW
program as
per heating
circuits
(factory
setting)
own WW-
program
(page 38)
DHW program
according to
heating
circuits and no
separate DHW
CP program
2)
(factory
setting)
2) No separate program has been set for DHW circulation, i.e. the times for the DHW circulation pump match
the times for the DHW program.
Separate
DHW
program
(page 38) and
no separate
DHW CP
program
2)
Separate
DHW CP
program
(page 38)
Absent:
complete
system
Holiday mode
(DHW off/
ECO)
Holiday mode (CP off)
Absent:
individual
heating
circuits
With all HC in
holiday mode:
holiday mode
(DHW off/
ECO)
No holiday
mode
If all HC set to
holiday: holiday
mode (CP off)
No holiday
mode
No holiday
mode
If at least one
HC not set to
holiday: no
holiday mode
3)
If at least one
HC not set to
holiday: no
holiday mode
3)
At home:
complete
system
As per
Saturday
switching
program
as WW
program for
Saturdays
3)
3) The earliest switch-on point and the latest switch-off point of all heating circuits on this day apply.
As per Saturday
switching
program
as WW
program for
Saturdays
3)
as ZP
program for
Saturdays
At home:
individual
heating
circuits
If all HC set to
holiday: same
as switching
program for
Saturdays
3)
No holiday
mode
If all HC set to
holiday: same as
switching
program for
Saturdays
3)
No holiday
mode
No holiday
mode
If at least one
HC not set to
holiday: no
holiday mode
3)
If at least one
HC not set to
holiday: no
holiday mode
3)
Table 14 Function of domestic hot water (DHW) and DHW circulation pump (CP) in holiday
mode