2.4 Technical data
2.4.1 Ambient conditions
Temperature range: +5 to +50 °C.
2.4.2 Connected load
The connected load is specified according to customer and country.
2.4.3 Aspiration
To achieve good performance when operating the machine, connect the machine to
an aspiration system.
Required air volume:
•10 m3/min (DFTA 12)
•12 m3/min (DFTA 13)
•15 m3/min (DFTA 23)
2.4.4 Weights
2.4.5 Determining the mesh widths
Choosing the correct sieve mesh width is critical for performance and sifting quality.
Choose the mesh widths for the sieve deck according to the following formula:
MW = desired grain size of throughs / 0.8
Select the closest standard mesh width.
Application limit: 2 mm (smallest possible mesh width).
2.4.6 Standard mesh widths
2.4.7 Noise data
Machine type DFTA 12 DFTA 13 DFTA 23
Weights [kg] 330 670 880
Standard mesh widths in [mm]
2.0 2.5 3.15 3.55 4.0 5.0 7.1 9.0 11.0 25.0
Measured data
Equivalent sound pressure level in the machine area L
eq
=77dB (A)