©2023 CAE 905K600152 v1.4 79
Using Juno
Post-Mastectomy Care
This optional module allows learners to practice post-mastectomy care.
To use the Post-Mastectomy wound kit:
1. Remove the female skin from Juno.
2.
Replace with the post-mastectomy skin.
3.
Place the end of a drainage system through the hole and underneath
the skin.
4.
Moulage the drainage.
Fundus Assessment
This optional module allows learns to train on fundus assessment and massage skills. It allows for the
uteri to be placed at different heights from delivery through day three.
The fundus can also be offset due to bladder distention with the ability to perform urinary
catheritization. Symphysis pubis and umbilicus landmarks are present.
Post-Mastectomy Wound Kit
The kit includes:
• Post
-operative left tota
l mastectomy
inc
ision with staples
• Opening for drain
tube to
be placed
un
der the skin
• Normal right breast