AVALON GALLERIA Rev. 8 04/2013
www.cafection.com (800) 561-6162
34
INSTALLATION AND SERVICE MANUAL for AVALON Galleria and Quatro
Cleaning & Sanitizing
5.4 Cleaning and Sanitizing Schedule
The cleaning schedule and instructions outlined in this manual must be followed to honor the warranty and
ensure consistent product quality and maintain health safety levels.
All parts should be visually inspected upon each visit and cleaned as needed.
Exterior Daily Weekly Monthly Quarterly As needed
Waste bin Inspect Clean
Canisters Inspect Clean
Drip tray
Clean
Unit + Stand Clean
Interior Daily Weekly Monthly Quarterly As needed
Brewer assembly Sanitize Clean Treatment Clean
Brewer chamber Sanitize Clean
Wipper & Mixing
bowls
Sanitize
Fan
Inspect Clean
3 beans canister Sanitize
Stainless coffee
chute
Clean
3 Beans canister
plastic chute
Clean
Rinse cycle Process
These recommendations are based on 1,000 cycles per month, medium blend coffee and superior
water quality levels . The above recommendations will need to be adjusted if the beverage volume,
coffee blends used and water quality differ.