Page #13 background image
RX TX
./ # .#

RX TX
10 11 TS 1 2 3 3P 4 5 7 CX CY CZ
10 11 TS 1 2 3 3P 4 5 7 CX CY CZ
10 11 TS 1 2 3 3P 4 5 7 CX CY CZ 2 3 3P 4 5 7 CX CY CZ
p.
13
13 - Manual code:
119 B J 04 E N
119BJ04EN v.
1
1 02/2015
© CAME Cancelli Automatici S.p.A. - The data and information in this manual may be changed at any time and without notice..
DFW
Photocells
Configure contact CX, CY or CZ (NC), input for EN 12978
safety devices like photocells.
See CX input functions (Function F2), CY (Function F3) or CZ
(Function F4) in:
- C1 reopening during closing. When the gate is closing,
opening the contact triggers the inversion of movement until
the gate is fully open;
- C2 reclosing during opening. When the gate is opening,
opening the contact triggers the inversion of movement until
the gate is fully closed;
- C3 partial stop. Stopping of the gate, if it is moving, with
consequent automatic closing (if the automatic closing
function has be entered);
- C4 obstruction wait. Stopping of the gate, if it is moving,
which resumes movement once the obstruction is removed.
If unused, contacts CX, CY and CZ should be
deactivated during programming.
DFW with control board for
DFI connections
DIR
photocells
DELTA-S
photocells
DELTA
photocells
Safety devices
Sensitive Safety Edges
Configure contact CX, CY or CZ (NC), input for
EN 12978 safety devices such as sensitive
safety-edges. See input CX functions (Function
F2), CY (Function F3) or CZ (Function F4)
in:- C7 reopening during closing. When the
gate is closing, opening the contact triggers
the inversion of movement until the gate is
completely open;
- C8 reclosing during opening. When the
gate is opening, opening the contact triggers
the inversion of movement until the gate is
completely closed.
If unused, contacts CX, CY and CZ
should be deactivated during programming.