Menu structure
F 1 – “Total stop” Function
F 2 – function assigned to CX input
F 3 – function assigned to CY input
F 5 – Safety test function
F 6 – maintained action function
F 7 – Command mode on 2-7
F 8 – Command mode on 2-3p
F 9 – Obstacle detection function when motor is stopped
F 10 – Warning light function
F 11 – Exclude Encoder function
F 12 – Slow start function
F 13 – Closing thrust function
F 14 – Sensor type selector function
F 16 – Ram head blow function (only for Myto – Amico – Frog J - Stylo RME motors)
F 17 – Lock function (only for Myto – Amico – Frog J - Stylo RME motors)
F 18 – Supplementary light function
F 19 – Automatic closing time
F 20 – Automatic closing time after partial opening
F 21 – pre-flashing time
F 22 – Working time
F 23 – Delay opening time
F 24 – Delay closing time
F 25 – Courtesy light time
F 26 – Ram head blow time (only for Myto – Amico – Frog J - Stylo RME motors)
F 27 – lock time (only for Myto – Amico – Frog J - Stylo RME motors)
F 28 – M1 motor speed adjustment
F 29 – M2 motor speed adjustment
F 30 – M1 motor speed slow-down time adjustment
F 31 – M2 motor speed slow-down time adjustment
F 32 – Additional closing slow down adjustment for M1 and M2 motors (only for Myto and Stylo with straight-arms)
F 33 – Calibration speed adjustment
F 34 – Sensitivity during movement
F 35 – Sensitivity during slow-downs
F 36 – Adjusting partial openings
F 37 – Adjusting the initial slow-down point of the M1 motor when opening
F 38 – Adjusting the initial slow-down point of the M1 motor when closing
F 39 – Adjusting the point the M1 motor begins drawing to the fully open position
F 40 – Adjusting the point the M1 motor begins drawing to the fully closed position
F 41 – Adjusting the initial slow-down point of the M2 motor when opening
F 42 – Adjusting the initial slow-down point of the M2 motor when closing
F 43 – Adjusting the initial drawing to stop point of the M2 motor when opening
F 44 – Adjusting the initial drawing to stop point of the M2 motor when closing
F 45 – Adjusting an additional slow-down point when closing (only for Myto and Stylo RME with straight-arms)
F 46 – Adjusting the number of motors
F 50 – Saving data in memory roll
F 51 – Reading memory roll data
U 1 – Type of command to associate to a user via radio command
U 2 – Cancelling single users
U 3 – Cancelling all user
A 1 – Setting the type of gearmotor
A 2 – Motor tests
A 3 – Gate run calibration
A 4 – Resetting parameters
H 1 – Software version