ESC < > ENTER
cl i
ESC < > ENTER
cl2
ESC < > ENTER
op2
ESC < > ENTER
op I
0
0
0
0
0
0
0
0
P. 25 - Manual code: 319V21EN Vers. 3 04/2017 © CAME cancelli automatici S.p.A. - The data and information in this manual are subject to change at any time without prior notice required by Came Cancelli Automatici S.p.A.
ENGLISH
1) Select “A3”.
Press ENTER to confirm.
2) Select 1 and press ENTER to confirm,
the automatic gate run calibration
procedure...
Gate run calibration
3) the gate leaf of the first motor will close
fully until the mechanical stop…
4) …then, the gate leaf of the second
motor will do the same…
5) …then, the gate leaf of the second
motor, shall fully open until the mechanical
stop…
6) …then, the gate leaf of the first motor
will do the same.
N.B: before proceeding with the calibration of the gate run, check that the area of movement is free of any obstacles and check
that there is a mechanical stop or both opening and closing.
Important! While calibrating, all safety devices will be disabled until the end of the calibration excluding the “total stop”