EasyManua.ls Logo

CAME zl92 - Page 26

CAME zl92
28 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
M2
M1
E
G
M
N
O
O
D
B
A
B
D
B
B
D
A
D
FH
O
C
C
Q
P
P
IL
P. 26 - Manual code: 319V21EN Vers. 3 04/2017 © CAME cancelli automatici S.p.A. - The data and information in this manual are subject to change at any time without prior notice required by Came Cancelli Automatici S.p.A.
ENGLISH
A = Area of movement at normal speed
B* = Run zone at slow-down speed
C = Encoder intervention zone with movement inversion
D= Encoder intervention zone with movement stop
E = Opening slow-down beginning point (M1 Open Slow- %)
F = Closing slow-down beginning point (M1 Close Slow- %)
G = Opening slow-down beginning point (M2 Open Slow- %)
H = Closing slow-down beginning point (M2 Close Slow- %)
I** = Point at which gate begins drawing to fully-closed position (M1 Close appr. %)
L** = Point at which gate begins drawing to fully-closed position (M2 Close appr. %)
M**= Point at which gate begins drawing to fully-open position (M1 Acc. AP%)
N**= Point at which gate begins drawing to fully-open position (M2Acc. AP%)
O = Mechanical Stops
P = Area in which additional slow- down speed takes place when closing, only for the straight-arm Stylo and Myto motors)
Q = Point at which additional slow-down when closing begins, only for the straight-arm Stylo and Myto motors)
Note: the slow-down areas and points at which the gate draws to the fully open or closed position are tested according to the
parameters set forth by Technical Norms EN12445 and EN12453 regarding compatibility of impact forces generated by moving
gate leaves.
* Minimum 600 mm from the Final full stop.
** Set the function’s approach % “M1 Close appr.” for the fi rst (M1) motor and “M2 Close appr.” for the second (M2) motor from
the “ENCODER” menu so as to obtain a distance of between 1 and 50 mm max. from the fi nal full stop.