F 13 (closing thrust) : at the closing endpoint, the gearmotors give the gate leaves a brief final-closing thrust.
0 = Deactivate (default setting); 1 = 1. = Minimum thrust 2. = Medium thrust 3. = Maximum thrust
F 14 (Type of sensor) : setting the type of sensor for the operator command via (TSP00) transponder or (LT001) magnetic card
reader with R700 encoder card or S7000 keyboard with R800 encoder card.
0 = TAG; 1 = S7000 (default setting).
F 16 (Ram head blow): before any opening run, the gate leaves will press onto the mechanical endstop for a few seconds, to help
release the electro-lock (to set the time, see “F26”).
Note: this function is only visible for the Myto, Frog.J, Stylo-RME and Amico gearmotors.
0 = Deactivate (default setting); 1 = Activate.
F 17 (Lock): releasing the electrolock while closing and opening (for time setting see “F27” function).
Note: Myto, Frog.J, Stylo-RME and Amico gearmotors.
0 = with opening command (default setting); 1 = with closing command; 2 = with both commands.
F 19 (Automatic Closing time) : The automatic closing timer activates at each opening endpoint. The predetermined time may be
adjusted, and is in any case dependent on any safety devices that may activate; and it does not activate after a total safety “stop”
or during a power outage.
The waiting time can be deactivated or set to between 1 and 180”.
0 = Deactivated (default setting); 1 = 1 second; 2 = 2 seconds; .................. 180 = 180 seconds.
F 18 (10-E Light) : output on contact 10-E for light with following function:
- movement flashing, flashes during gate opening and closing.
- outdoor lamp that can be freely positioned, for additional lighting of the driveway – is set up as a courtesy light and stays on for
an adjustable time interval (see function “F25) or as a cycle light, which stays on from the moment the gate leaf begins to open,
until it is fully closed (including automatic closing time).
0 = Flashing light (default setting); 1 = Cycle; 2 = Courtesy.