Motors test and calibration menu
A 1 (Motor type) : setting up the type of swing gate gearmotor installed.
1 = Stylo ME with jointed-arm; 2 = Stylo ME with straight arm; 3 = Myto; 4 = Frog-J; 5 =
Amico; 6 = Stylo RME with jointed-arm; 7 = Stylo RME with straight arm
A 2 (motors test) : activating the test to verify the proper turning direction of the gearmotors (see “motors test” paragraph).
0 = Deactivated; 1 = Activated.
A 3 (Calibrating the gate run) : automatic calibration of the gate run on both gearmotors (see “gate run calibration” paragraph).
0 = Deactivated; 1 = Activated
A 4 (Reset parameters): data resetting (default setting) and cancelling the gate run calibration.
0 = Deactivated; 1 = Activated.
IMPORTANT! Before setting adjusting any functions, set which gearmotors are installed in the system (A 1 – Motor type),
check the gate’s proper direction of travel of (A 2 – Motors test) and calibrate the gate run (A 3 – Gate run calibration)
Note: press ENTER to confirm after choosing each function value.