P. 19 - Manual code: 319V21EN Vers. 3 04/2017 © CAME cancelli automatici S.p.A. - The data and information in this manual are subject to change at any time without prior notice required by Came Cancelli Automatici S.p.A.
ENGLISH
F 37 (Slow-down point when opening the M1 motor) : adjusts the point at which the M1 motor begins to slow down when ope-
ning. The beginning slow-down point is calculated as a percentage of the full gate run (see paragraph illustrating the slow-down
areas and points)
10 = 10% of the gate run; .................. 25 = 25% of the gate run (default setting); .................. 60 = 60% of the gate run.
F 38 (Slow-down point when closing the M1 motor) : adjusts the point at which the M1 motor begins to slow down when
closing. The beginning slow-down point is calculated as a percentage of the full gate run (see paragraph illustrating the slow-down
areas and points)
10 = 10% of the gate run; .................. 25 = 25% of the gate run (default setting); .................. 60 = 60% of the gate run.
F 39 (Point when M1 motor draws fully open) : adjusts the point at which the M1 motor begins drawing to the fully-open posi-
tion
This point is calculated as a percentage of the full gate run (see paragraph illustrating the slow-down areas and points)
1 = 1% of the gate run; .................. 5 = 5% of the gate run (default setting); ..................10 = 10% of the gate run.
F 40 (Point when M1 motor draws fully closed) : adjusts the point at which the M1 motor begins drawing to the fully-closed
position.
This point is calculated as a percentage of the full gate run (see paragraph illustrating the slow-down areas and points at which
gate draws fully open or closed.)
1 = 1% of the gate run; .................. 5 = 5% of the gate run (default setting); .................. 10 = 10% of the gate run.
F 41 (Point when M2 motor is fully open) : adjusts the point at which the M2 motor begins to be fully-open.
The beginning slow-down point is calculated as a percentage of the full gate run (see paragraph illustrating the slow-down areas
and points at which gate draws fully open or closed)
10 = 10% of the gate run; .................. 25 = 25% of the gate run (default setting); .................. 60 = 60% of the gate run.
F 42 (Slow-down point when closing the M2 motor) : adjusts the point at which the M2 motor begins to slow down when
closing. The beginning slow-down point is calculated as a percentage of the full gate run (see paragraph illustrating the slow-down
areas and points at which gate draws fully open or closed)
10 = 10% of the gate run; .................. 25 = 25% of the gate run (default setting); .................. 60 = 60% of the gate run.