3
3
3-27
3-27
Disassembly/Assembly > Fixing System > Removing the Fixing Unit
Disassembly/Assembly > Fixing System > Removing the Fixing Unit
Fixing System
Removing the Fixing Unit
Preparations
1) Remove Left Cover.(Refer to page 3-9)
2) Remove Right Cover.(Refer to page 3-9)
3) Remove Rear Cover Unit.(Refer to page 3-10)
4) Remove Duplex Reverse Sensor Unit.
Procedure
CAUTION:
When removing the xing assembly, perform the operation after the xing assembly is
surely cooled.
The xing assembly just after printing may cause burn injury.
1) Close Front Cover and remove 3 gears.
F-3-48
Points to Note at Installation:
Fit the Protrusion [2] of the Gear [1] With the Cut-off of the Gear [3] and Install it.
Fit the Cut-off [4] of the Gear [1] With the Teeth of the Fan Gear [5] and Install it.
[1]
[1]
[2]
[5]
[3]
[4]
F-3-49