212/212X Installation & Technical
8200-M639-O1 Rev D 09/14
A-HLD= (Auto-Hold Feature for Animal Weighing)
Press the ENTER key to show the current setting. If the setting
displayed is acceptable, press the ENTER key again to save it.
Otherwise, using the numeric keys, enter the new setting and then
press the ENTER key to save it. Allowable settings are 0, 1 or 2.
Disabled (Next setup prompt is SLEEP=)
Standard Mode (Held weight is cleared 3 seconds after
animal is removed)
Advanced Mode (Held weight is not cleared. New held
weight is displayed after next animal is weighed)
THRES= (Minimum Auto-Hold Weight)
Press the ENTER key to show the current setting. If the setting
displayed is acceptable, press the ENTER key again to save it.
Otherwise, using the numeric keys, enter the new setting and then
press the ENTER key to save it. Allowable settings are any
number between 0 and scale capacity.
A-ACC= (Auto-Accumulate Weight)
This feature automatically accumulates weight whenever Auto-
Hold is actuated.
Press the ENTER key to show the current setting. If the setting
displayed is acceptable, press the ENTER key again to save it.
Otherwise, using the numeric keys, enter 0/NO or 1/YES and then
press the ENTER key to save it.
BALTOL (Balance Tolerance)
This feature corrects instability when weighing animals. The
entered tolerance setting is the maximum amount the scale can
fluctuate and still allow the auto-hold to actuate.
Press the ENTER key to show the current setting. If the setting
displayed is acceptable, press the ENTER key again to save it.
Otherwise, using the numeric keys, enter the new setting and then
press the ENTER key to save it. Allowable settings are 0 to 99.