SLEEP= (Sleep Mode)
The Sleep Mode feature conserves battery power when the indicator
remains unused for a period of approximately 1 to 9 minutes. When
enabled, the load cell excitation will be reduced and the display will be
blank.
The Sleep Mode feature requires the indicator to remain at the center of
zero to activate, unlike Automatic Shutoff feature which only requires no
motion. Weight placed on the scale will activate the indicator and return it
to the weight mode.
Press the ENTER key to show the current setting. If the setting displayed
is acceptable, press the ENTER key again to save it. Otherwise, use the
numeric keys to enter a new setting and then press the ENTER key to
save it. Allowable settings are 0 through 9 with 0 disabling Sleep Mode.
A oFF= (Auto Shutoff)
The Automatic Shutoff feature will automatically turn the indicator off after
a period of approximately 1 to 9 minutes of inactivity to prolong battery life.
You must press the ON/OFF key to turn the indicator back on.
Press the ENTER key to show the current setting. If the setting displayed
is acceptable, press the ENTER key again to save it. Otherwise, use the
numeric keys to enter a new setting and then press the ENTER key to
save it. Allowable settings are 0 through 9 with 0 disabling Auto Shutoff.