CALIBRATION and SETUP, Cont.
OPERATIONAL SETUP, Cont.
COUNT ACCURACY
The display will show C acrC acr, the prompt to select the Count Accuracy percentage and
display the current setting. This refers to the set-point for the INSUFFICIENT SAMPLE
annunciator. There are two pre-selected values, .1 and .5 percent. If the weight of a sample
is less than .1% or .5% of the gross capacity of the scale, (.1 lb or .5 lb for a 100 lb capacity
scale) sample accuracy is not guaranteed. The Insufficient Sample annunciator will
illuminate, and the scale will calculate the minimum additional number of pieces required to
raise the sample weight to the .1% or .5% preset and display the quantity.
To change the setting, use the numeric keypad to key-in a new value (1 or 5, with no decimal)
for the count accuracy, then press the ENTER key to save the setting and proceed to the
next prompt.
AUTO SHUTOFF
The display will show a offa off, the prompt to enable or disable the Auto Shutoff feature and
display the current setting. This feature, when enabled will automatically turn the scale off
after a select period of inactivity to prolong battery life. To turn the instrument back on you
must toggle the power switch from the ON position to the OFF position and then back to the
ON position.
To change the setting, using the numeric keypad, key-in the number of minutes (1 through 9,
time approximate) of inactivity before turning the scale off, then press the ENTER key to save
the setting and proceed to the next prompt. Note, that entering a zero (0) disables the
Automatic Shutoff feature.
DISPLAY INTENSITY
The display will show britebrite, the prompt to adjust the display intensity and display the current
setting. This feature allows the display intensity (brightness) to be adjusted to compensate for
lighting conditions at the scale's location. Also, when operating from the battery, lowering the
display intensity decreases the load on the battery, increasing operating time before
recharging is required. To change the setting, use the numeric keypad to key-in a new value
(1 to 3) for the display intensity, then press the ENTER key to save the setting and proceed to
the next prompt.
1 = DIM 2 = NORMAL (default setting) 3 = HIGH
CLEAR MEMORY
The display will show clr rclr r, the prompt to enable the Clear Memory operation and display
the current (default) setting NO. This operation, when enabled will clear all ID's and
associated accumulators from the scale memory. The Clear Memory operation is performed
after turning the scale OFF and back ON with YES selected for the setup prompt. After
clearing memory, the setup prompt will automatically return to NO, the default setting.
NOTE: The Clear Memory operation does not clear the Calibration or Setup
information from the scale. The Calibration and Setup data are stored in non-volatile
memory (NOVRAM) and can only be changed using their respective procedures.
To enable the Clear Memory operation, press the YES/1 key, then press the ENTER key to
save the setting and proceed to the next prompt.
28