“Ultrasound for fancoil” +0300059IE - rel. 1.7 - 24.10.2022
15.1 Ultrasound humidier models for fan coils and electrical specications
The table below summarises the electrical data (power supply voltages) of the various models, as well as their functional characteristics. Note that some
models can be powered at dierent voltages, obviously with dierent current and humidity production values.
power supply
model humidity production
(2; 4)
(kg/h) power
(2)
(W) code voltage
(1)
(V - type) current
(2)
(A) cable
(3)
(mm
2
)
UU01FD 0,5 60 D 230-1~ 0,75 1,5
UU01F1 0,5 60 1 115 - 1~ 0,6 1,5
UU01GD 1 110 D 230 - 1~ 1,5 1,5
UU01G1 1 110 1 115 - 1~ 1,2 1,5
Tab. 15.a
(1) tolerance allowed on rated mains voltage: -15%, +10%;
(2) tolerance on rated values: +5%, -10% (EN 60335-1);
(3) recommended values, referring to PVC or rubber cable in a closed conduit, 20 m (65.6 ft) long; compliance with standards in force is always required;
(4) max instant rated water vapour production: average water vapour production may depend on external factors, such as: room temperature, water quality, water vapour distribution
system.
NOTICE: to avoid interference, keep power cables separate from probe cables.
15.2 Technical specications
Technical specications UU models
UU01*
humidity outlet
connection dia. mm 40 (ensure an outlet area of 1100 mm2, e.g. 22 x 8 mm holes)
supply water
connection G 1/8” F
temperature limits °C (°F) 1...40 (33.8....104)
pressure limits (MPa) 0,1...0,6 (1...6 bar)
specic conductivity at 20°C 3...50 μS/cm
total hardness 0...25 mg/l CaCO3
temporary hardness 0...15 mg/l CaCO3
total quantity of dissolved solids (cR) depending on specic conductivity
(1)
dry residue at 180°C depending on specic conductivity
(1)
iron + manganese G 1/8” F
chlorides 1...40 (33.8....104)
silicon dioxide 0,1...0,6 (1...6 bar)
chlorine ions 0...50 μS/cm
calcium sulphate 0...25 mg/l CaCO3
instant ow-rate (l/min) 0...15 mg/l CaCO3
drain water
connection dia. mm (“) 10 mm
instant ow-rate (l/min) 7
environmental conditions
ambient operating temperature °C (°F) 1...45 (33.8...113)
ambient operating humidity (% rH) 10...80
storage temperature °C (°F) -10...60 (14...140)
storage humidity (% rH) 5 to 95 (41 to 203)
index of protection IP00
electronic controller
auxiliary voltage/frequency (V- Hz) 24 V / 50-60 Hz
maximum auxiliary power (VA) 3
control signal inputs (general features) can be selected for the following signals: 0 to 10 Vdc, 2 to 10 Vdc, 0 to 20 mA, 4 to 20 mA,
input impedance: 20 kΩ with signals: 0 to 10 Vdc, 2 to 10 Vdc
100 Ω with signals: 0 to 20 mA, 4 to 20 mA
alarm relay outputs (general features) 24 V (max 3 W)
remote enabling signal input (general features) voltage-free contact; max. resistance 100 Ω; Vmax= 5 Vdc; Imax= 5 mA
power
instant water vapour production
(2)
kg/h (lb/h) see table above
power consumption at rated voltage (W) see table above
Tab. 15.b
(1)
= in general C
R
0,65 * σ
R,20 °C
; R
180
0,93 * σ
R, 20 °C
(2 )
= average water vapour production is aected by factors such as: room temperature, water quality, water vapour distribution system