6. Error Messages
Error 1
The PLU number you have called up does not exist.
Error 2
The PLU number you have called up is out of range.
Error 3
The weight on the platter is not stable or you have pressed the keys
before the weight became stable.
Error 4
Tare weight was set.
Error 5
PLU data is corrupted or broken. Backup RAM, initialize the scale,
re-enter the bad data, and load new data into scale.
Error 6
You have pressed the PRT/* while the Printer Control Switch was in STOP mode.
Error 7
The RS-232C cable that you are using is not wired properly, possible
break in the cable, or communications error.
Error 8
Impossible to transfer PLU data between two scales. Remove unit price
by pressing C key.
Error 9
You have an RS-232C communication error, please try again.
Error 10
The tare weight you entered was not valid: re-enter tare weight.
Error 11
The tare weight you entered was out of range.
Error 12
Loaded weight is below minimum weight of OIML regulation.
Error 14
You have pressed the PRT/* key after the label roll was exhausted.
Exchange the label roll, press the C key and release the error message.
Adjust the initial printing state by pressing the FEED key. The label roll you
used was broken away from the interrupt sensor : replace the label roll
between the two green sensor caps and fix the label roll pin.
Error 15
You attempted to print a label when there is an issued label, please remove the
issued one. You have pressed PRT/* key when the printer front cover is not placed
properly. You attempted to print a label when the print head is in the lifted-up :
push it down and it is issued a label paper automatically.
Error 16
Mode key is not property pressed. EX) During PLU call-up, MODE key is pressed
following massage will appear.
Error 17
Tray was not empty when FOR key is pressed. (Except the American region)
Error 18
TARE key it not property pressed when unit price and weight is on scale.
Error 19
Wrong setting value of scale capacity, such as Cal4 mode (kg or lb)
Error 20
Wrong setting on CAL4 Unit set.
Error 21
Wrong setting on CAL4 DP set.
Error 22
Over-range in ZERO Range
Zero range
Error
Initial weight is not valid. Make sure platter is properly installed
SCALE is not stable : scale is installed on a unstable place
dO CAL :
Setup data is broken.