68
7. Specifications
MODEL LP-1000
CAPACITY RESOLUTION
30.00 Lbs x 0.01 Lbs (15.000 kg x 0.005kg)
TARE
-30.00 Lbs ~ -0.01 Lbs (-5.99 kg ~ -0.005kg)
WEIGHT DISPLAY
UNIT PRICE DISPLAY
TOTAL PRICE DISPLAY
4 DIGITS (USA) 5 DIGITS (EX - USA)
4 DIGITS (USA) 6 DIGITS (EX - USA)
4 DIGITS (USA) 7 DIGITS (EX - USA)
CONDITIONS:
TEMPERATURE RANGE
POWER
22 ~ 95 (℉℉-5 ~ 35 )℃℃
85 VAC ~ 265 VAC 50 / 60 Hz ± 3 Hz
MEMORY
CAPACITY
4000 PLU
1000 PLU
INGREDIENT DATA
400 CHARACTER
LABEL TYPES
58 x 30 mm (#8000)
58 x 40 mm (#8010)
58 x 60 mm (#8020)
58 x 50 mm (#8030)
58 x 60 mm (#8040)
COMMODITY NAME
2 LINES OF 28 CHARACTERS EACH = 56
CHARACTERS PER COMMODITY
DIRECT PLU KEYS
54 PRESET KEYS
8. Trouble Shooting
PROBLEMS REMARKS
x Scale does not work at all.
x No light on the display & the power
switch is ON.
x Check the fuse located to the left of the power switch.
x Try plugging scale into a different electrical socket.
x Scale counts up to 9's & then
goes blank.
x Scale counts up to 9's & then shows:
"Zero rAnGE Error"
x Remove everything from the platter. Turn scale OFF and then ON.
x Make sure platter is proper installed and nothing is obstructing
the platter from underneath.
x Call your CAS Dealer for SPAN calibration.
x Scale does not accept Tare.
x Make sure that the Tare being entered is within 0.01~30.00 Lbs.
x Make sure that the NET lamp is off before trying to enter a Tare.
x In spite of pressing the TARE key,
the Tare does not clear.
x Make sure all items are removed from the platter & then try again.
x Remove all items from the platter and thenm turn scale OFF & ON.
x After push the PRT / * button scale
not work at all.
x Check the PEEL sensor.