OAuth on each gateway. For the user using Cassia RESTful API in
the container, it is not necessary to do OAuth authentication.
Remote Assistance
Turn this on will enable Cassia engineers to remotely access the
gateway for troubleshooting purposes. By default, this function is off.
Cassia gateway configuration page -- Basic
The network uplink traffic between the gateway and the AC includes Bluetooth Low
Energy traffic and management traffic. There are two ways to reduce the uplink
management traffic.
1. The user can change the Statistic Report Interval to 1, 2, or 5 minutes
2. The user can select MQTT as the Data Path on the AC Settings page in v1.4, or
select MQTT as AC-Gateway communication protocol on the gateway web page
in v2.0.
Below are examples of network uplink management traffic with different configurations
(not including Bluetooth Low Energy traffic).
Firmware & Configuration
CAPWAP
control + data
(MB per month)
CAPWAP control
MQTT data path
(MB per month)
MQTT
control + data
(MB per month)
v1.3 (w/o container)
255 (DL 58, UL 197)
N/A in v1.3
N/A
v1.3 (w/ container)
390 (DL 58, UL 332)
N/A in v1.3
N/A