Assembly and operating instructions
CENTAX-G
020G-00050…00090-F.10
CENTA Antriebe Kirschey GmbH 42 / 52
7 Operation
Injury and material damage can occur as a result of:
Worn coupling components
If the running noises change and/or vibrations occur turn the plant off
immediately.
Determine the fault and its root cause, and remedy.
The troubleshooting process is simplified by the table in the next chapter.
On principle in case of a fault, an analysis of the entire plant should be
performed.
7.1 Operating faults, root causes and remedy
Prior to all kinds of remedies
Running noises or
vibrations in the unit
Check alignment and correct
Check screw torque levels and correct
Membrane or rubber
element damaged
Check alignment and correct
Replace defective parts
Eliminate the cause for inadmissibly
high torque
Table 7-1 Troubleshooting table
In case of uncertainty or if you have questions, please contact our head office
(address see chapter 1).
7.2 Admissible overall misalignment of the coupling
The overall misalignment values can be found in the catalogue.