page 10 www.centsys.com
R6 Standard-Torque Operator
Gate Length (m) 1.5 2 2.5 3
2
3.5
2
4
2
4.5
2
5
2
Gate Height (m) 1.8 1.8 1.8 1.8 1.8 1.8 1.8 1.8
Max Mass (Kg) 500 500 480 330 240 185 145 120
Allowable Wind
Speed for 25%
Clad (Km/h)
1
114 84.7 67.3 56.9 49.2 43.2 38.6 34.8
Allowable Wind
Speed for 100%
Clad (Km/h)
1
57 42.4 33.6 28.5 24.6 21.6 19.3 17.4
R6 High-Torque Operator
Gate Length (m) 1.5 2 2.5 3
2
3.5
2
4
2
4.5
2
5
2
Gate Height (m) 1.8 1.8 1.8 1.8 1.8 1.8 1.8 1.8
Max Mass (Kg) 750 750 620 430 315 240 190 155
Allowable Wind
Speed for 25%
Clad (Km/h)
1
128.4 95 76.3 64.6 55.9 49.2 43.9 39.6
Allowable Wind
Speed for 100%
Clad (Km/h)
1
64.2 47.5 38.1 32.3 27.9 24.6 21.9 19.8
TABLE 2
TABLE 3
SPECIFICATIONSSECTION 2
2.2.1. Gate Specications
1. No wind opening time ~ 12s. Gate opening and closing times will increase as wind speed increases.
2. Fit an electric gate lock if the leaf width is greater than 3 metres.
1. No wind opening time ~ 15s. Gate opening and closing times will increase as wind speed increases.
2. Fit an electric gate lock if the leaf width is greater than 3 metres.