page 9 www.centsys.com
2.2. Technical Specications
R6
Input Voltage
CP13E CP84SM
220V - 240V AC
+/-10% @ 50Hz
1
90V - 240V AC
+/-10% @ 50Hz
1
Motor Voltage 12V DC
Current Consumption
(mains)
CP13E - 80mA
CP84SM - 170mA
Maximum DC Current Draw 16A
Maximum Output Torque
Standard-torque
operator
300Nm
High-torque
operator
390Nm
Power Supply
Domestic 0.8A CP13E, 7.2Ah Battery
Light-industrial 1.8A CP84SM, 7.2Ah Battery
Industrial 1.8A CP84SM, 33Ah Battery
Maximum Daily Operations
DL = Double Leaf
SL = Single Leaf
Mains present Back-up
2
DL SL DL SL
Domestic 20 30 20 30
Light-industrial 250 250 40 60
Industrial 250 250 250 250
Maximum Daily
Continuous Operations
DL = Double Leaf
SL = Single Leaf
Mains present
DL SL
Domestic 20 30
Light-industrial 50 50
Industrial 100 100
Typical Gate Operating
Time
Standard-torque
operator
12s
High-torque
operator
15s
Mass of Motor Kit
3
(excluding pedestal or wall
bracket)
15kg
Collision Sensitivity Electronic - Adjustable
Temperature Range -15°C to +50°C
Housing Protection IP55
Packaging Dimensions 255mm wide x 375mm deep x 320mm high
TABLE 1
SPECIFICATIONSSECTION 2
1. Canoperateoasolarsupply,pleaseconsultCenturionSystems(Pty)Ltdforassistance.
2. These values are based on fully charged batteries, derate accordingly based on connected ancillaries.
3. The weight of an operator kit (regardless of Master or Slave).