EasyManua.ls Logo

CENTURION SYSTEMS R6 - Pedestal Positioning (Gate Inward Opening)

CENTURION SYSTEMS R6
48 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
page 17 www.centsys.com
Step 2
Swing the gate to the desired
opening position (70 - 120 degrees)
and make the second mark “S2” on
the ground.
Step 3
Measure the distance “Z”, between
“S1” & “S2” in mm, then using “Z”,
look up gate opening Angle and
dimension C for size of Drive Arm
supplied (see Table 5).
FIGURE 8
S1
S2
Z
6.3.1. Pedestal Positioning (Gate Inward Opening)
Z
GATE OPENING
ANGLE
DIMENSION C FOR DRIVE ARMS
250mm 400mm 500mm
1147 70° 436 697 872
1161 71° 431 689 861
1176 72° 425 681 851
1190 73° 420 672 841
1204 74° 415 665 831
1218 75° 411 657 821
1231 76° 406 650 812
1245 77° 402 643 803
1259 78° 397 636 795
1272 79° 393 629 786
1286 80° 389 622 778
1299 81° 385 616 770
1312 82° 381 610 762
1325 83° 377 604 755
1338 84° 374 598 747
TABLE 5
OPERATOR INSTALLATIONSECTION 6
Say “Z” is measured as
1482mm, then the closest
Z value in table = 1486mm.
Dimension “C” for a 400mm
Drive Arm is therefore
538mm.