MANUALPC-2012 CHAPTER I – INTRODUCTION Page 5
PROGRAM MENUS
Initial Screens
When power is applied to the controller, CHEMTROL® PC
displays the Welcome Screen shown on the right. It includes
the firmware version of the operating software installed on the
controller and the factory’s Technical Support phone numbers.
Canada has the same toll-free support numbers as the USA.
These screens can also be accessed at any time from the
Main Display Screen by pressing the LEFT ARROW key.
Display Screens
The Welcome Screen is followed by the main menu showing
the main functions of the controller and their conditions.
The adjustable operational information are shown from left to
right as follows:
1. Operational status arrow indicating outlet activation,
2. Function identification: ORP, SANITIZER, pH,
CONDUCTIVITY, TEMPERATURE, PUMP and FILTER,
3. Function/Sensor readings,
4. Units of measurement (US or metric),
5. Function operational mode:
A: Automatic control,
M: Manual operation,
T: Timer control,
X: OFF.
Main Menus and Submenus
As shown on the Menu Tree included in the manual, there are
several submenus that are accessed directly from the Main
Screen; one for each operating function, and one for system
configuration.
Navigation through the menus is done with the four arrow keys
located on the front panel keypad. To access any menu or
submenu, use the UP and DOWN ARROW keys to highlight
the desired function and press the RIGHT ARROW key. To
exit from any submenu or screen, press the LEFT ARROW
key.
Alarm Displays
Probe failure, out-of-range and overfeed conditions are
indicated on the main screen and submenues with flashing
lines. For probe failure, the display flashes “Probe” on the
corresponding line.
If the display shows an out-of-range or overfeed alarm
condition, press the DOWN ARROW key to the flashing line
and enter that function’s submenu with the RIGHT ARROW
key to determine the cause of alarm.
Welcome Screen
PC5000/7000 Main Display
PC2100 Main Display
WELCOME TO
CHEMTROL® 6000
Version 2.16
TECHNICAL SUPPORT
USA 800-621-2279
PHONE 805-683-8833
FAX 805-683-1893
>ORP
mV
A
SANITIZER 1.0 ppm X
>ACID 7.5 pH A
COND 2000 uS X
TEMP 82 F A
>PUMP 200 gpm A
FILTER 25 / 20 psi X
08/10/11 5:30 LSI OK
>ORP
mV
A
SANITIZER 1.4 ppm X
>pH 6.7 pH A
COND 1730 uS X
TEMP 79 F A
FLOW 2 4 gpm X
06/03/12 12:47 OK