EasyManuals Logo

Chino KP3000 User Manual

Default Icon
88 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #36 background imageLoading...
Page #36 background image
- 33 -
8 type parameter No. 1
FNC code……Application function code, R/W……R: READ, W: WRITE
Reference
number
FNC
Code
R/W Data name
Setting range
(Communication
range)
Initial
value
Remarks
40221
03
06
16
R
W
W
[8 type parameter]
Time signal ON,
No.1
'Hours’ or
‘Minutes'
0 to 999
(0 to 999)
000
(Hours
or
minutes)
Can be written when there is external
signal input.
Setting of HHH of HHH:LL
Unit = Every time unit
1) In case of H:M (hours:minutes), H (hours)
2) Incase of M:S (minutes:seconds), M (minutes)
40222
03
06
16
R
W
W
[8 type parameter]
Time signal ON,
No.1
'Minutes’ or
‘Seconds'
0 to 59
(0 to 59)
00
(Minutes
or
seconds)
Can be written when there is external
signal input.
Setting of LL of HHH:LL
Unit = Every time unit
1) In case of H:M (hours:minutes), H (hours)
2) Incase of M:S (minutes:seconds), M (minutes)
40223
03
06
16
R
W
W
[8 type parameter]
Time signal OFF,
No.1
'Hours’ or
‘Minutes'
0 to 999
(0 to 999)
000
(Hours
or
minutes)
Can be written when there is external
signal input.
Setting of HHH of HHH:LL
Unit = Every time unit
1) In case of H:M (hours:minutes), H (hours)
2) Incase of M:S (minutes:seconds), M (minutes)
40224
03
06
16
R
W
W
[8 type parameter]
Time signal OFF,
No.1
'Minutes’ or
‘Seconds'
0 to 59
(0 to 59)
00
(Minutes
or
seconds)
Can be written when there is external
signal input.
Setting of LL of HHH:LL
Unit = Every time unit
1) In case of H:M (hours:minutes), H (hours)
2) Incase of M:S (minutes:seconds), M
(minutes)
8 type parameter No. 2
FNC code……Application function code, R/W……R: READ, W: WRITE
Reference
number
FNC
Code
R/W Data name
Setting range
(Communication
range)
Initial
value
Remarks
40271
03
06
16
R
W
W
[8 type parameter]
Time signal ON,
No.2
'Hours’ or
‘Minutes'
0 to 999
(0 to 999)
000
(Hours
or
minutes)
Can be written when there is external
signal input.
Setting of HHH of HHH:LL
Unit = Every time unit
1) In case of H:M (hours:minutes), H (hours)
2) Incase of M:S (minutes:seconds), M (minutes)
40272
03
06
16
R
W
W
[8 type parameter]
Time signal ON,
No.2
'Minutes’ or
‘Seconds'
0 to 59
(0 to 59)
00
(Minutes
or
seconds)
Can be written when there is external
signal input.
Setting of LL of HHH:LL
Unit = Every time unit
1) In case of H:M (hours:minutes), H (hours)
2) Incase of M:S (minutes:seconds), M (minutes)
40273
03
06
16
R
W
W
[8 type parameter]
Time signal OFF,
No.2
'Hours’ or
‘Minutes'
0 to 999
(0 to 999)
000
(Hours or
minutes)
Can be written when there is external
signal input.
Setting of HHH of HHH:LL
Unit = Every time unit
1) In case of H:M (hours:minutes), H (hours)
2) Incase of M:S (minutes:seconds), M (minutes)
40274
03
06
16
R
W
W
[8 type parameter]
Time signal OFF,
No.2
'Minutes’ or
‘Seconds'
0 to 59
(0 to 59)
00
(Minutes
or
seconds)
Can be written when there is external
signal input.
Setting of LL of HHH:LL
Unit = Every time unit
1) In case of H:M (hours:minutes), H (hours)
2) Incase of M:S (minutes:seconds), M (minutes)

Table of Contents

Other manuals for Chino KP3000

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Chino KP3000 and is the answer not in the manual?

Chino KP3000 Specifications

General IconGeneral
BrandChino
ModelKP3000
CategoryController
LanguageEnglish