- 34 -
8 type parameter No.3
FNC code……Application function code, R/W……R: READ, W: WRITE
Reference
number
FNC
Code
R/W Data name
Setting range
(Communication
range)
Initial
value
Remarks
40321
03
06
16
R
W
W
[8 type parameter]
Time signal ON,
No.3
'Hours’ or
‘Minutes'
0 to 999
(0 to 999)
000
(Hours
or
minutes)
Can be written when there is external
signal input.
Setting of HHH of HHH:LL
Unit = Every time unit
1) In case of H:M (hours:minutes), H (hours)
2) Incase of M:S (minutes:seconds), M (minutes)
40322
03
06
16
R
W
W
[8 type parameter]
Time signal ON,
No.3
'Minutes’ or
‘Seconds'
0 to 59
(0 to 59)
00
(Minutes
or
seconds)
Can be written when there is external
signal input.
Setting of LL of HHH:LL
Unit = Every time unit
1) In case of H:M (hours:minutes), H (hours)
2) Incase of M:S (minutes:seconds), M (minutes)
40323
03
06
16
R
W
W
[8 type parameter]
Time signal OFF,
No.3
'Hours’ or
‘Minutes'
0 to 999
(0 to 999)
000
(Hours
or
minutes)
Can be written when there is external
signal input.
Setting of HHH of HHH:LL
Unit = Every time unit
1) In case of H:M (hours:minutes), H (hours)
2) Incase of M:S (minutes:seconds), M (minutes)
40324
03
06
16
R
W
W
[8 type parameter]
Time signal OFF,
No.3
'Minutes’ or
‘Seconds'
0 to 59
(0 to 59)
00
(Minutes
or
seconds)
Can be written when there is external
signal input.
Setting of LL of HHH:LL
Unit = Every time unit
1) In case of H:M (hours:minutes), H (hours)
2) Incase of M:S (minutes:seconds), M
(minutes)
8 type parameter No.4
FNC code……Application function code, R/W……R: READ, W: WRITE
Reference
number
FNC
Code
R/W Data name
Setting range
(Communication
range)
Initial
value
Remarks
40371
03
06
16
R
W
W
[8 type parameter]
Time signal ON,
No.4
'Hours’ or
‘Minutes'
0 to 999
(0 to 999)
000
(Hours
or
minutes)
Can be written when there is external
signal input.
Setting of HHH of HHH:LL
Unit = Every time unit
1) In case of H:M (hours:minutes), H (hours)
2) Incase of M:S (minutes:seconds), M (minutes)
40372
03
06
16
R
W
W
[8 type parameter]
Time signal ON,
No.4
'Minutes’ or
‘Seconds'
0 to 59
(0 to 59)
00
(Minutes
or
seconds)
Can be written when there is external
signal input.
Setting of LL of HHH:LL
Unit = Every time unit
1) In case of H:M (hours:minutes), H (hours)
2) Incase of M:S (minutes:seconds), M (minutes)
40373
03
06
16
R
W
W
[8 type parameter]
Time signal OFF,
No.4
'Hours’ or
‘Minutes'
0 to 999
(0 to 999)
000
(Hours
or
minutes)
Can be written when there is external
signal input.
Setting of HHH of HHH:LL
Unit = Every time unit
1) In case of H:M (hours:minutes), H (hours)
2) Incase of M:S (minutes:seconds), M (minutes)
40374
03
06
16
R
W
W
[8 type parameter]
Time signal OFF,
No.4
'Minutes’ or
‘Seconds'
0 to 59
(0 to 59)
00
(Minutes
or
seconds)
Can be written when there is external
signal input.
Setting of LL of HHH:LL
Unit = Every time unit
1) In case of H:M (hours:minutes), H (hours)
2) Incase of M:S (minutes:seconds), M
(minutes)

Table of Contents