Refertoinstallationand wiringoperationfromchapter
Screendisplaynormal,default is50.00Hz
SETTINGF2.22TO2,PRESSING
RUN KEYFORSTATICSELF-
LEARNING
SETTINGF2.22TO1,
PRESSINGRUN
KEYFORSTATICSELF-LEARNING
SET5.00Hztocheckthemotordirection
AfterconfirmingthatthemotorcanRUN,themotorisunloadedandrun
accordingto"Run"onthepaneltomeasurethethree-phasecurrentbalance
Afterconfirmingthatthemotorrunsnormallywithoutload,ifitcanbeloaded,
themotorrunswithload,andconfirmtomeasurethethree-phasecurrentbalance
deniercurrentandlessthanmotorratedcurrent
Basicdebuggingcompleted,shutdown,accordingtotheequipmentprocess
requirements
DebugotherparametersRecordthecurrentvalueofthetestandtheparameter
valueofthedebugging.Afterthebasicdebuggingiscompleted,
stop,setother controlparameters,
andrunaccordingtotheactualworkingcondition
Comparing to the motor name
plate to set the rotor paremeter
correctly of F2.01~2.06 from F2
group
Confirming the main
Circuit wiring correct
Power up after
conformation
Selecting control
model by F0.00
Setting motor parameter
according to the motor
actural parameter
parameter self-learning
or not
Releaseing the motor
load or not
Adjusting acceleration and
deceleration time according to
working condition
Jogging debug device
Keyboard number is the set
operation frequency by default
Setting by F0.14(acceleration time)
and F0.15(deceleration time)
Figure 7-10 Basic debugging operation diagram
034
NVF2G-S Series Inverter User's Guide