Local Operation
3. Setting the Short Time
The range of short time is from 0 to 30 Sec. The short time must be SEQuence ON
time. If the short channel is not selected or the short time is set to 0 Sec., the selected
channel will not short. The default setting is channel 0 and 0 Sec.
SEQ. 1
SHORT TIME= 0.0S
4.2.4 Running the Program
Press ON/OFF to run program when program function is selected. The LED channel
indicators will be active if the channel is active. The display shows as follows.
PROG. 1 SEQ. 1
[ON][KEY][PASS]
The upper line appears the executed program and sequence number while the lower line
shows the result status of Load, key and test.
ON/OFF: It shows Load input status.
KEY: It appears when MANUAL mode is active and waiting for key input.
PASS/FAIL: It shows the test result compared with SPEC setting.
When the program is executed, the setting sequence will recall files from EEPROM, and the
SPEC function is always ON. All function keys are disabled until ON/OFF is pressed to
stop the program execution, or the program run finishes. When the program run stops or
finishes, the LCD will show as follows.
PROGRAM OFF
RESULT :PASS
It means that all sequences are passed in the test program. If the test fails, LCD will show as
follows.
PROG. XX : 1 2
3 4 5 6 7 8
9 10
PROG. XX indicates the file number the program fails, 1 to 10. In addition, 1, 2, 3...10
shown by LCD indicate the failed sequence numbers. The failed sequences are the results of
all failed channels. The channel LED will also indicate the failed channel. During the
program chain testing, if the failed program files are more than one set, you can use to
read the contents of failed programs.
4.2.5 Setting the Specification
The SPEC key is to enable/disable SPEC function, or selects the settings of specifications.
The Load will compare measurement data with the set specifications of HIGH and LOW
4-9