115
Update
The scanner allows configuring in which format the collected data will be output to the
host computer. Barcode read by the scanner will be processed in the following
sequence –
1) Perform character substitution on the data scanned.
2) Add
Code ID and Length Code to the front of the data:[Code ID][Length Code][Data]
3) Process the whole data in step 2 with user formats. Data is now divided into fields by
user specified rules. Refer to
Chapter 5 Applying Formats for Data Editing.
4) Add
Prefix Code and Suffix Code before transmission:[Prefix Code][Processed
Data][Suffix Code]
IN THIS CHAPTER
4.1 Letter Case ..............................................................115
4.2 Character Substitution...............................................116
4.3 Prefix/Suffix Code .....................................................128
4.4 Code ID...................................................................129
4.5 Length Code ............................................................136
4.6 Multi-Barcode Editor..................................................144
4.7 Removal of Special Character .....................................148
4.1 LETTER CASE
By default, the alphabets transmission is case-sensitive, meaning that the alphabets will
be transmitted according to their original case. Ignoring the original letter case, select
[Upper Case] to output data in upper case only; otherwise, select [Lower Case] to output
data in lower case only.
*Normal
Upper Case
Lower Case
Chapter 4
DEFINING OUTPUT FORMAT