Chapter 5
Applyin
g
Formats for Data Editin
g
5.4.4 FIELD SETTINGS
Data eligible for editing formats is divided into fields by user-specified rules – either
using the field terminating string or specified field length.
By Terminating String
Specify the field terminating string. Up to two characters are allowed. The scanner will search for
the occurrence of this particular string in the data.
By default, this string will be included in the field.
By Length
Alternatively, Simply specify the field length. The scanner will assign the next specified number of
characters into the field.
Field 1 Setting
1. Read the barcode below to divide field 1 by a specified terminating string.
S
elect
F
ield Separator
to Divide Field 1…
2. Read the “Hexadecimal Value” barcode on page 194 for the desired character string.
3. Read the “Validate” barcode to complete this setting.
4. Read the “Discard Separator” barcode if the field separator is not desired in the field.
*Include Separator
Discard Separator
If not dividing the field by a specific separator, divide it by a specified length.
1. Read the barcode below to divide field 1 by length.
D
ivide Field 1
by Length
2. Read the “Decimal Value” barcode on page 193 for the desired field length.
3. Read the “Validate” barcode on the same page to complete this setting.