2-13
Catalyst 4500 Series Switch Cisco IOS System Message Guide
OL-13091-01
Chapter 2 Messages and Recovery Procedures
CHASSIS Messages
Error Message C4K_CHASSIS-4-SUFFICIENTPOWERRESTORED: Resuming normal operation
after restoration of adequate power
Explanation
The switch reset the modules to conserve power, but it now has adequate power and will
resume normal operation.
Recommended Action This is an informational message only. No action is required.
Error Message C4K_CHASSIS-4-TDRTESTINPROGRESS: TDR test is in progress on interface
[char]
Explanation
The TDR test is already in progress on this interface.
Recommended Action Try the command again after the test is completed.
Error Message C4K_CHASSIS-4-TESTNOTSUPPORTEDONPORT: [char] is not supported on this
port
Explanation
The online diagnostic test requested cannot be run on the specified port.
Recommended Action This is an informational message only. No action is required.
Error Message C4K_CHASSIS-4-TESTNOTSUPPORTEDONPORTCONNECTOR: [char] is not
supported on port connector type: [char]
Explanation
This online diagnostic test cannot be run on the specified port with the current connector
type. If the connector type changes to copper, it may be possible to run the test.
Recommended Action This is an informational message only. No action is required.
Error Message C4K_CHASSIS-4-UNSUPPORTEDTRANSCEIVER: Unsupported transceiver found
in [char]
Explanation
The transceiver was identified as an unsupported non-Cisco transceiver.
Recommended Action If this transceiver was purchased from Cisco, contact Cisco TAC to get the
transceiver replaced.
Error Message C4K_CHASSIS-7-SYSTEMMEMORYINSTALLED: [dec] MB of system memory
installed. Do 'show platform hardware sdram spd' for details.
Explanation
This tells how much memory has been installed, on supervisor engines s having more
than one DIMM slot.
Recommended Action This is an informational message only. No action is required.