2-71
Catalyst 4500 Series Switch Cisco IOS System Message Guide
OL-13091-01
Chapter 2 Messages and Recovery Procedures
LINECARDMGMTPROTOCOL Messages
LINECARDMGMTPROTOCOL Messages
This section contains the module management protocol (LINECARDMGMTPROTOCOL) messages.
Error Message C4K_LINECARDMGMTPROTOCOL-3-FAILEDTOSEND: EsmpDriver [char] - Failed to
send ESMP requests due to [char].
Explanation
This message indicates a failure in ESMP request generation for the reason given. This
is probably due to high CPU utilization caused by a number of factors, and under these
circumstances switching module communication protocol packets can not be transmitted.
Recommended Action If you see this message frequently, analyze the traffic going to the CPU and
contact your technical support representative to debug the problem.
Error Message C4K_LINECARDMGMTPROTOCOL-4-INITIALTIMEOUTWARNING:
[char] - management request timed out.
Explanation
There are communication problems with the module ASIC that fans out a single gigabit
port to front-panel ports. A few messages are within tolerance levels.
Recommended Action This is an informational message only. No action is required. If this message is
seen frequently, refer to: http://www.cisco.com/en/US/products/hw/switches/ps663/
products_tech_note09186a00801c9221.shtml
Error Message C4K_LINECARDMGMTPROTOCOL-4-ONGOINGTIMEOUTWARNING:
[char] - consecutive management requests timed out.
Explanation There are persistent communication problems with the module ASIC that fans out a
single gigabit port to front-panel ports.
Recommended Action Reinsert the module.
LOGGING REDIRECT Messages
This section contains the Logging Redirect ISSU messages.
Error Message LOGGING_REDIRECT_ISSU-2-GET_BUFFER: Logging Redirect ISSU client
failed to get buffer for message. Error: [dec] ([char])
Explanation The Logging Redirect ISSU client failed to get buffer space for building a negotiation
message. A negotiation message cannot be sent to the standby device. If a problem occurs with the
ISSU session negotiation, the standby device cannot be brought up properly.
Recommended Action Copy the error message exactly as it appears on the console or in the system
log. Issue the show logging and show checkpoint client commands to gather data that may help
identify the nature of the error. Research and attempt to resolve the error using the Output Interpreter
at https://www.cisco.com/cgi-bin/Support/OutputInterpreter/home.pl. Issue the show tech-support
command to gather data that may helpidentify the nature of the error. Also perform a search of the