2-54
Catalyst 4500 Series Switch Cisco IOS System Message Guide
OL-13091-01
Chapter 2 Messages and Recovery Procedures
IOSMODPORTMAN Messages
Error Message C4K_IOSMODPORTMAN-4-MODULETEMPHIGH: Module [dec] Sensor [char]
temperature is at or over threshold - CurrentTemp: [dec]C, Threshold: [dec]C
Explanation
The module temperature is above its threshold. If the temperature goes above critical
threshold, another message will be logged and the system will shut down to prevent damage to
hardware.
Recommended Action Inspect the module and find out why it is heating up.
Error Message C4K_IOSMODPORTMAN-4-MODULETEMPUNDERCRITICAL: Module [dec] Sensor
[char] temperature is now under critical threshold but still very high - current
temp: [dec]C, critical threshold: [dec]C
Explanation
This message is sent when a module temperature returns to below critical threshold.
Recommended Action This is an informational message only. No action is required. The module
temperature may still suggest a problem with the module.
Error Message C4K_IOSMODPORTMAN-6-MODULETEMPOK: Module [dec] Sensor [char]
temperature is now ok - CurrentTemp: [dec]C, Threshold: [dec]C
Explanation This message is sent when module temperature returns back to normal.
Recommended Action This is an informational message only. No action is required.
Error Message C4K_IOSMODPORTMAN-4-SSOMODULEOLDVERSION: Received stale
acknowledgement for the linecard in slot [dec]: expected [dec], received [dec].
Explanation
This is most probably the result of a linecard being rapidly removed and reinserted.
Recommended Action This is an informational message only. No action is required.
Error Message C4K_IOSMODPORTMAN-4-FANTRAYBAD:Fan tray has failed
Explanation
The fan tray failed.
Recommended Action Replace the fan tray as soon as possible.
Error Message C4K_IOSMODPORTMAN-4-FANTRAYPARTIALFAILURE: A fan or thermistor/s in
system fan tray have failed
Explanation
This is a warning message indicating that one or more fans or thermal sensors in the
system fan tray have failed.
Recommended Action Schedule a time to replace the fan tray soon. System performance should not
be immediately affected.

Table of Contents

Other manuals for Cisco Catalyst 4500 Series

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Cisco Catalyst 4500 Series and is the answer not in the manual?

Cisco Catalyst 4500 Series Specifications

General IconGeneral
SeriesCatalyst 4500 Series
CategorySwitch
Layer SupportLayer 2, Layer 3
Form FactorModular chassis
StackableNo
Chassis Slots3, 6, 7, 10
Power Supply OptionsAC, DC
RedundancyPower supply, Supervisor engine
Network ManagementCisco IOS Software CLI, SNMP, Cisco Prime Infrastructure
FeaturesSecurity, QoS
Port DensityUp to 384 ports per chassis
Security Features802.1X, ACLs, DHCP Snooping, Dynamic ARP Inspection, IP Source Guard
Supervisor Engine8-E

Related product manuals