Catalyst 4500 Series Switch Cisco IOS System Message Guide
OL-13091-01
Chapter 2 Messages and Recovery Procedures
IOSMODPORTMAN Messages
Error Message C4K_IOSMODPORTMAN-4-FANTRAYREMOVED:Fan tray has been removed
Explanation
The fan tray was removed.
Recommended Action This is an informational message only. No action is required.
Error Message C4K_IOSMODPORTMAN-4-FANTRAYGOOD:Fan tray is okay
Explanation The fan tray passed all tests and is operating normally.
Recommended Action This is an informational message only. No action is required.
Error Message C4K_IOSMODPORTMAN-4-INLINEPOWERSUPPLYBAD: Inline power from power
supply [dec] has failed or been turned off
Explanation
A PoE source from a power supply failed or was turned off. The hardware cannot make
a distinction between the two cases.
Recommended Action Verify that the incoming power is good, and if it is replace the power supply as
soon as possible.
Error Message C4K_IOSMODPORTMAN-4-NFLABSENT: Netflow Services Card absent or idprom
invalid on [char] supervisor.
Explanation
The recommended configuration for using the NetFlow Services Card is to have it
installed on both the standby and active supervisor engines. Otherwise, during switchover, the
system might lose its NetFlow capabilities.
Recommended Action Verify that the NetFlow Services Card is installed on both supervisor engines.
Error Message C4K_IOSMODPORTMAN-4-NFLIDPROMINVALID: Netflow Services Card has
invalid idprom on [char] supervisor
Explanation
The IDPROM on the NetFlow Services Card on the supervisor engine indicated in the
message is invalid.
Recommended Action Contact your technical support representative.
Error Message C4K_IOSMODPORTMAN-4-NFLMISMATCH: Netflow Services Cards have
mismatched [char]. ([dec] on [char] and [dec] on [char]).
Explanation The IDPROM attributes of the NetFlow Services Cards installed on the active and the
standby supervisor engines do not match.
Recommended Action Verify that the NetFlow Services Card is correctly installed on both supervisor
engines.