Cisco FLUIDMESH FM4200 Mobi Specifications

General IconGeneral
CategoryTransceiver
ModelFM4200 Mobi
Data RateUp to 300 Mbps
Power Supply9-36 VDC
Channel Bandwidth5, 10, 20, 40 MHz
ModulationQAM, QPSK, BPSK
Operating Temperature-40°C to +70°C
Power Consumption10W (typical)
Antenna Connector2 x N-Type

Summary

Hazardous Condition Warnings

1.1. Water ingress hazard

Details the hazard of water ingress and required precautions for outdoor installations.

1.2. Radio-frequency transmission hazard

Explains RF exposure limits and minimum separation distances for safe operation.

1.3. Hot surfaces hazard

Warns about hot unit surfaces during operation and the need for protective equipment.

Reporting Mistakes and Recommending Improvements

Getting Started

3.1. Introduction

Provides an overview of the Cisco FM4200 Mobi radio transceiver.

Installing the Radio

4.1. Installing the radio using tie-wraps or hose clamps

Step-by-step guide for mounting the radio transceiver using tie-wraps or hose clamps.

4.2. Installation on a DIN rail

Instructions for mounting the radio transceiver unit onto a DIN rail.

4.3. Installation using the sliding bracket

Procedure for installing the unit using a quick-release sliding bracket.

Hardware Installation

5.1. Fluidmesh Hardware Installation

Details the initial hardware installation procedures for Fluidmesh devices.

5.2. Connecting the Fluidmesh Cisco FM4200 Mobi to a network and antennas

Explains how to connect the FM4200 Mobi to network and antennas.

Using the Fluidmesh Partner Portal

6.1. Accessing the Partner Portal

Guides on how to access the Fluidmesh Partner Portal and register.

6.2. Enabling Two-Factor Authentication for security

Steps to set up and enable two-factor authentication for enhanced security.

6.3. Administering plug-in license codes

Describes tasks available for managing license codes via the Partner Portal.

6.4. Using the RACER™ radio configuration interface

Explains how to access and use the RACER™ web-based configuration portal.

6.5. Viewing the technical documentation for your Fluidmesh device

Guides on finding technical documentation for Fluidmesh devices on the Partner Portal.

Device Configuration Using the Configurator Interface

7.1. Software and hardware prerequisites

Lists the necessary software and hardware for configuring the FM4200 Mobi.

7.2. Accessing the Cisco FM4200 Mobi for device configuration

Details methods to access the FM4200 Mobi for configuration.

7.3. Switching between offline and online modes

Instructions on how to switch between offline and online modes in the Configurator.

7.4. General settings

Covers general settings like operational mode, Prodigy version, and LAN parameters.

7.4.2. Wireless settings

Covers modifying wireless settings like passphrase, country, frequency, and channel width.

7.4.3. Antenna-alignment tools and physical statistics

Describes tools for monitoring link status and adjusting antenna alignment.

7.4.4. Spectral analysis

Explains how to use the Spectrum Graph for detecting RF interference.

7.5. Network control

Covers network control features including Ping softdog and FM-QUADRO.

7.5.3. Advanced tools

Tools for diagnosing wireless network conditions, including Ping, Bandwidth, and Path MTU tests.

7.6. Advanced settings

Covers advanced configuration options for radio parameters and network settings.

7.7. Management settings

Covers management settings like view mode, changing credentials, and firmware upgrades.

Software Plug-Ins

8.1. Available plug-ins

Lists all available software plug-ins, their functions, and part numbers.

8.2. Plug-in management procedures

Standardized procedures for managing plug-ins across all Fluidmesh hardware devices.

Troubleshooting

9.1. I cannot get the Log-in screen

Troubleshooting steps for issues accessing the login screen for device configuration.

9.2. I cannot log in to the FM Racer interface

Solutions for problems logging into the FM Racer web-based configuration interface.

9.3. I forgot the Administrator password

Steps to take if the Administrator username or password for the Configurator interface is forgotten.

9.4. The wireless link is poor or non-existent in Bridge mode

Checks to improve wireless link strength when it is poor or non-existent in Bridge mode.

Electrical Power Requirements

Heat Radiation Data

Federal Communications Commission (FCC) Radio Interference Statement

Notices and Copyright

Fluidmesh End-User License Agreement

14.1. Preamble

Introduces the terms and prohibitions of the Fluidmesh Firmware license agreement.

14.2. Notice

An agreement between user and Fluidmesh regarding firmware terms.

14.3. Definitions

Defines key terms used within the Fluidmesh End-User License Agreement.

14.4. License grant

Grants a non-exclusive, non-transferable license to use Fluidmesh Firmware.

14.5. Uses and restrictions on use

Outlines permitted uses and restrictions for Fluidmesh Firmware and devices.

14.6. Open-source software

Addresses the acknowledgment and compliance with Open Source Software licenses.

14.7. Termination

Details conditions for license termination and consequences of unauthorized use.

14.8. Feedback

Policy regarding user suggestions, comments, and other feedback.

14.9. Consent to use of data

Acknowledges Fluidmesh's right to collect and use device data for service improvement.

14.10. Warranty disclaimer

Disclaims warranties for Fluidmesh Firmware, devices, and documentation.

14.11. Limitation of liability

Limits Fluidmesh's liability for damages arising from firmware or device supply/use.

14.12. Exclusion of liability for emergency services

Excludes liability for emergency calls or services through Fluidmesh products.

14.13. Export control

States compliance requirements with U.S. export control laws and regulations.

14.14. General

General terms and conditions governing the license agreement.

Contact Us

Related product manuals