2-23
Cisco IE 3000 Switch System Message Guide
OL-13020-01
Chapter 2 Message and Recovery Procedures
FLASH_DEVICE Messages
FLASH_DEVICE Messages
This section contains the flash device messages.
Error Message FLASH-1-DEVICE_REMOVED: Flash device removed
Explanation The compact flash card has been removed from the switch. There is no access to the
flash file system.
Recommended Action To access the flash file system, reinsert the compact flash card.
Error Message FLASH-6-DEVICE_INSERTED: Flash device inserted
Explanation The compact flash card has been inserted into the switch. There is now access to the
flash file system.
Recommended Action No action is required.
GBIC_SECURITY Messages
This section contains the Cisco Gigabit Interface Converter (GBIC) and small form-factor pluggable
(SFP) module security messages. The GBIC and SFP modules have a serial EEPROM that contains the
serial number, security code, and cyclic redundancy check (CRC). When the module is inserted into the
switch, the software reads the EEPROM to recompute the security code and CRC. The software
generates an error message if the CRC is invalid or if the recomputed security code does not match the
one stored in the EEPROM.
Note The Cisco IE 3000 switch supports SFP modules and does not support GBIC modules. Although the
error message text refers to GBIC interfaces and modules, the messages from the switch actually refer
to the SFP module interfaces and modules.
Error Message GBIC_SECURITY-4-EEPROM_CRC_ERR: EEPROM checksum error for GBIC in
[chars].
Explanation The GBIC in the specified port has invalid EEPROM data. [chars] is the port in which
the GBIC is inserted.
Recommended Action Remove the GBIC from the port.
Error Message GBIC_SECURITY-4-EEPROM_READ_ERR: Error in reading GBIC serial ID in
[chars].
Explanation An error occurred while the switch was reading the GBIC type from the EEPROM.
[chars] is the port in which the GBIC is inserted.
Recommended Action Remove the GBIC from the port.

Table of Contents

Other manuals for Cisco IE-3000-8TC

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Cisco IE-3000-8TC and is the answer not in the manual?

Cisco IE-3000-8TC Specifications

General IconGeneral
Switching Capacity16 Gbps
MAC Address Table Size8000
Uplink Ports2 x 10/100/1000Base-T or SFP (Small Form-Factor Pluggable)
Operating Temperature-40°C to 70°C
MountingDIN rail
Ports8 x Ethernet 10/100Base-TX ports
Jumbo Frame SupportYes