2-44
Cisco IE 3000 Switch System Message Guide
OL-13020-01
Chapter 2 Message and Recovery Procedures
PM Messages
Error Message PM-4-LIMITS: The number of vlan-port instances on [chars] exceeded the
recommended limit of [dec].
Explanation The total number of individual VLAN ports, counted over the module or switch, has
exceeded the recommended limit. VLANs can be counted more than once; if VLAN 1 is carried on
ten interfaces, it will count as ten VLAN ports. On some platforms bundling is also ignored for
purposes of this count; if eight interfaces on the same module are in one bundle, and the port channel
is carrying VLAN 1, it will count as eight VLAN ports. [chars] is the module name (for example,
switch or the module number), and [dec] is the recommended limit.
Recommended Action Reduce the number of trunks and VLANs configured in the module or switch
as recommended in [dec]. Enter the show interfaces trunk privileged EXEC command to see the
total number of trunks and VLANs.
Error Message PM-4-NO_SUBBLOCK: No PM subblock found for [chars].
Explanation The port manager failed to find the subblock for this interface. [chars] is the interface
name.
Recommended Action Copy the message exactly as it appears on the console or in the system log.
Research and attempt to resolve the error by using the Output Interpreter. Enter the show
tech-support user EXEC command to gather data that might help identify the nature of the error.
Use the Bug Toolkit to look for similar reported problems. If you still require assistance, open a case
with the TAC, or contact your Cisco technical support representative, and provide the representative
with the gathered information. For more information about these online tools and about contacting
Cisco, see the
“Error Message Traceback Reports” section on page 1-4.
Error Message PM-4-PORT_BOUNCED: Port [chars] was bounced by [chars].
Explanation During a switchover when the port was in the link-down state, the port manager
restarted the port. A port can be restarted only when the port data structures are not consistent in the
active and standby supervisors. Active ports in the link-down state are returned to the link-up state
when the port is restarted (the re-activation event). The first [chars] is the port number, and the
second [chars] is the re-activation event.
Recommended Action No action is required.
Error Message PM-4-PVLAN_TYPE_CFG_ERR: Failed to set VLAN [dec] to a [chars] VLAN.
Explanation The platform failed to set a private VLAN type. [dec] is the VLAN ID.
Recommended Action Copy the message exactly as it appears on the console or in the system log.
Research and attempt to resolve the error by using the Output Interpreter. Enter the show
tech-support user EXEC command to gather data that might help identify the nature of the error.
Use the Bug Toolkit to look for similar reported problems. If you still require assistance, open a case
with the TAC, or contact your Cisco technical support representative, and provide the representative
with the gathered information. For more information about these online tools and about contacting
Cisco, see the
“Error Message Traceback Reports” section on page 1-4.

Table of Contents

Other manuals for Cisco IE-3000-8TC

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Cisco IE-3000-8TC and is the answer not in the manual?

Cisco IE-3000-8TC Specifications

General IconGeneral
Switching Capacity16 Gbps
MAC Address Table Size8000
Uplink Ports2 x 10/100/1000Base-T or SFP (Small Form-Factor Pluggable)
Operating Temperature-40°C to 70°C
MountingDIN rail
Ports8 x Ethernet 10/100Base-TX ports
Jumbo Frame SupportYes