Table 67: Fabric Module LEDs
DescriptionStatusLED
All diagnostics pass. The module is operational (normal initialization
sequence).
GreenStatus
The diagnostic test has failed. The module is not operational because
a fault has occurred during the initialization sequence.
or
The inlet air temperature of the system has exceeded the safe
operating temperature limits of the card (a major environmental
warning). The card has been shut down to prevent permanent damage.
Red
The fabric module has just been inserted and is booting up.
or
An overtemperature condition has occurred and the module has
powered down.
or
The power was turned off with a CLI command.
or
The module is resetting and both ejector levers are out.
Flashing red
The operator has activated this LED to identify this module in the
chassis.
Flashing blueID
This module is not being identified.Off
Power Supply LEDs
Table 68: Power Supply LEDs , on page 249 describes the power supply unit LEDs. The Output, Fault, and
ID LEDs have the same function for the AC, DC and HVAC/HVDC power supply units.
Table 68: Power Supply LEDs
ConditionColorLED
The AC, HVAC/HVDC or DC input voltage
is within the valid range.
GreenInput 1
The AC, HVAC/HVDC or DC input voltage
is outside the valid range.
Off
The DC input voltage is within the valid
range.
GreenInput 2 (available only on DC
power supply units)
Cisco Nexus 7000 Series Hardware Installation and Reference Guide
249
Chassis and Module LEDs
Power Supply LEDs