SpecificationCharacteristic
32º to 122ºF (0º to 50ºC)
32º to 122ºF (0º to 50ºC)
32º to 158ºF (0º to 70ºC)
32º to 158ºF (0º to 70ºC)
32º to 122ºF (0º to 50ºC)
32º to 122ºF (0º to 50ºC)
Operating temperature
X2-10GB-ER
X2-10GB-LR
X2-10GB-LRM
X2-10GB-LX4
X2-10GB-SR
X2-10GB-ZR
–40º to 185º F (–40º to 85ºC)Storage temperature
10GBASE-DWDM X2 Transceivers
The Dense Wavelength Division Multiplexing (DWDM) X2 transceivers are part of a DWDM optical network
to provide high-capacity bandwidth across a fiber-optic network. As listed in Table 52: DWDM X2 Transceivers
, on page 222, there are 32 fixed-wavelength DWDM X2 transceivers that support the International
Telecommunications Union (ITU) 100-GHz wavelength grid. These transceivers have duplex SC connectors.
DWDM X2 transceivers can transmit and receive optical signals up to 50 miles (80 km) depending on the
quality of the fiber-optic cable used.
DWDM X2 transceivers look like the typical 10GBASE-X X2 transceivers as shown in Figure 148: 10-Gigabit
X2 Transceiver (Latching Sleeve Not Extended), on page 219.
For the specifications that differentiate the 10GBASE-DWDM X2 transceivers, see the http://www.cisco.com/
en/US/partner/docs/interfaces_modules/transceiver_modules/compatibility/matrix/OL_6974.html.
Table 52: DWDM X2 Transceivers
Description100-GHz ITU ChannelPart Number
10GBASE-DWDM 1560.61 nm X221DWDM-X2-60.61=
10GBASE-DWDM 1559.79 nm X222DWDM-X2-59.79=
10GBASE-DWDM 1558.98 nm X223DWDM-X2-58.98=
10GBASE-DWDM 1558.17 nm X224DWDM-X2-58.17=
10GBASE-DWDM 1556.55 nm X226DWDM-X2-56.55=
10GBASE-DWDM 1555.75 nm X227DWDM-X2-55.75=
10GBASE-DWDM 1554.94 nm X228DWDM-X2-54.94=
10GBASE-DWDM 1554.13 nm X229DWDM-X2-54.13=
10GBASE-DWDM 1552.52 nm X231DWDM-X2-52.52=
10GBASE-DWDM 1551.72 nm X232DWDM-X2-51.72=
Cisco Nexus 7000 Series Hardware Installation and Reference Guide
222
Transceivers and Module Connectors
10GBASE-DWDM X2 Transceivers