22 TD2-1 105 95 45 Ok
22 TD2-2 105 95 41 Ok
22 VRM-1 110 100 49 Ok
22 VRM-2 110 100 47 Ok
27 OUTLET 75 55 29 Ok
27 INLET 60 42 20 Ok
27 CPU 90 80 27 Ok
28 OUTLET 75 55 27 Ok
28 INLET 60 42 22 Ok
28 CPU 90 80 33 Ok
29 CPU 105 95 40 Ok
30 CPU 105 95 34 Ok
switch#
Connecting to a Module
You can connect to any module by using the attach module slot_number command. When the module prompt
appears, you can obtain further details about the module by using module-specific commands in EXEC mode.
You can also use the attach module command to display the standby supervisor module information, although
you cannot configure the standby supervisor module using this command.
To see which slots are filled with modules, use the show inventory command.Note
Use the attach module slot_number command to get direct access to a specific module.
This example shows how to attach to the supervisor in slot 28.
switch# attach module 28
Attaching to module 28 ...
To exit type 'exit', to abort type '$.'
Cisco Nexus Operating System (NX-OS) Software
TAC support: http://www.cisco.com/tac
Copyright (c) 2002-2013, Cisco Systems, Inc. All rights reserved.
The copyrights to certain works contained in this software are
owned by other third parties and used and distributed under
license. Certain components of this software are licensed under
the GNU General Public License (GPL) version 2.0 or the GNU
Lesser General Public License (LGPL) Version 2.1. A copy of each
such license is available at
http://www.opensource.org/licenses/gpl-2.0.php and
http://www.opensource.org/licenses/lgpl-2.1.php
switch(standby)#
To exit the module-specific prompt, use the exit command.Note
If you are not accessing the switch from a console terminal, this command is the only way to access the
standby supervisor module.
Tip
This command reports on only software-controlled modules, such as supervisors, system controllers, line
cards, fabric modules, fan trays, and power supplies. It does not report on modules that are not controlled
by software, such as blank modules installed in empty slots to control airflow.
Note
Cisco Nexus 9508 NX-OS Mode Switch Hardware Installation Guide
58
Managing the Switch
Connecting to a Module