Page #79 background imageLoading...
Page #79 background image
n+n redundancy mode
This mode allocates half of the power to available power and the other half to reserve power. You must
use a different power source for the active and reserve power sources so that if the power source used
for active power fails, the other power source used for the reserve power can provide power for the
switch.
For example, if the switch requires 4.0 kW of power, the switch has four power supplies that each
output 3 kW. If you have two power grids, you use grid A to power two 3-kW power supplies that
provide the available power for the switch and you use grid B to power the other two 3-kW power
supplies that provide the reserve power in case grid A fails.
Power Mode Configuration Guidelines
The amounts of available and reserve power depend on the power redundancy mode that you specify and the
number of power supplies installed in the switch. For each redundancy mode, consider the following:
Cisco Nexus 9508 NX-OS Mode Switch Hardware Installation Guide
69
Managing the Switch
Power Mode Configuration Guidelines

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Cisco Nexus 9508 and is the answer not in the manual?

Cisco Nexus 9508 Specifications

General IconGeneral
Product NameCisco Nexus 9508
CategorySwitch
Chassis Slots8
Rack Units13 RU
Switching CapacityUp to 60 Tbps
Form FactorModular chassis
LatencySub-microsecond
Operating SystemCisco NX-OS
AirflowFront-to-back
CoolingRedundant, hot-swappable fan trays
Uplink PortsDependent on line card configuration
Management Port1 x RJ-45 management port
PortsDependent on line card configuration
RedundancyN+1 or N+N power supply redundancy