Figure 50: Retention Feature and Ground Strap CableStandard Door
Step 9 Place the ground strap cable (see Figure 50: Retention Feature and Ground Strap Cable—Standard Door, on
page 56) on the door and the chassis and tighten the nuts to a torque value of 11.5 in-lb (1.3 N-m) to lock the
cable.
Step 10 Tighten the door screws to a torque value of 6.5 in-lb (0.75 N-m) to close the standard door as shown in the
following figure.
Installing the ONS 15454 M6 Shelf
56
Installing the ONS 15454 M6 Shelf
NTP-G258 Install the Standard Door of the ONS 15454 M6 Shelf