Figure 3: Removing a Compute Node Blank
Installing a Compute Node Blank
If you remove a compute node, and you will not be installing another compute node, you must install a node
blank (UCSX-9508-FSBK). Do not operate the UCS X9508 chassis with an empty compute node slot. The
minimum configuration is 1 installed compute node, so in this configuration you need 7 module blanks
installed.
Compute node blanks are interchangeable within the same chassis or other Cisco UCS X9508 chassis.
Use this task to install a compute node blank
Step 1 Grasp the blank by the finger holds.
Step 2 Hold the module blank vertically and align the module blank with the slot.
Cisco UCS X210c M6 Compute Node Installation and Service Note
10
Installing a Compute Node
Installing a Compute Node Blank