EasyManuals Logo

CODEL EnergyTech 100 Series User Manual

Default Icon
76 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #75 background imageLoading...
Page #75 background image
CODEL
OPS. 141 67
Issue : A
Revision : 1
Date : 14/06/18
Doc i/d : 0118/6
050028
Temperature Correction
Usually there is little change in temperature between the measured and exit
points, but where it is appreciable the stack exit opacity will be modified. This is
due to the gases reducing in volume while the particulate volume remains
relatively constant.
This correction is applied by expressing the effect in terms of measurement
path length as follows :
L
m
= L
mm
(273 + T
x
) / (273 + T
m
)
Where : Lm = Temperature-corrected effective path length,
Lmm = Actual measurement path length,
Tm = Temperature
o
C at measurement,
Tx = Temperature
o
C at stack exit.

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the CODEL EnergyTech 100 Series and is the answer not in the manual?

CODEL EnergyTech 100 Series Specifications

General IconGeneral
BrandCODEL
ModelEnergyTech 100 Series
CategoryMeasuring Instruments
LanguageEnglish

Related product manuals