ComNav T300 + CGSurvey User Guide
18
Field data collection.
Go to the A1-A5 points and start the field data collection.
Each section of observation please write down the station name, receiver SN,
start time and end time, also antenna height.
The data collect flow.
If you have 3 receivers, we suggest fixing them in 1,A1,A3, after the first section
observation, power off the receiver on 1 and take it to the points A5(A2 or A4);
after the second section, power off the receiver on A1 and move to A4; finally
take 1 receiver on point 2.
If you have more than 3 receivers, we suggest you fix two receivers on point 1&2,
and go to other points to collect data.
4.4 Raw Data Download
This section explains how to download data by CRU software.
The raw data is saved in T300 internal memory. So you need to download the data
from receiver to your office computer.